New: solar camera trailers for rent, by the monthReserve one
Electromagnetic entry · All 5 boroughs

Mag lock installation in NYC

An electromagnet that keeps the entrance shut until the right person comes through, then lets go by itself when the fire alarm sounds. iGTD Technology puts them on lobbies, offices, stores, stairwells and gates across the five boroughs.

NY State licensed installerWired to the fire alarmFob, PIN, fingerprint or phone

Free estimate in 60 seconds

Step 1 of 2 · What do you need?
Step 2 of 2 · Where should we call?

For: Access control

Or call 929-299-8400, Mon to Fri

Where is it going?

Pick the entrance and how people should get through it. The card shows what we put there and what to send us first. It can also open from the intercom when you buzz someone in, as part of a building intercom installation.

The entrance

How people get in

What NYC code asks of a mag-locked way out

Put a magnet on an exit and the 2022 NYC Building Code has rules for it, section 1010.1.9.8. The numbers on the drawing match the list, and we plan every install around all six. The code allows these locks in offices, stores, restaurants, schools, hotels and apartment buildings. A warehouse or factory exit is not on that list, and we will say so on the visit.

PUSH TO EXIT1234
  1. 1
    A sensor on the inside

    It hangs on the way-out side and picks up anyone walking toward the exit, then unlocks it. Item 1.

  2. 2
    A release button at hand height

    Between 40 and 48 inches off the floor and no more than 5 feet away. Pressing it cuts power to the magnet directly, apart from the other electronics, and keeps it open for at least 30 seconds. Item 3.

  3. 3
    The sign

    The button is marked with a sign that reads PUSH TO EXIT. Item 3.

  4. 4
    Power out means open

    If the building loses power, the magnet lets go on its own. Item 2.

  5. 5
    The fire alarm wins

    When the fire alarm, sprinklers or fire detection go off, it unlocks and stays that way until the alarm is reset. Items 4 and 5.

  6. 6
    Listed parts

    The locking hardware has to carry a UL 294 listing. Item 6.

Across the city in 2025, tenants filed 2,392 HPD complaints about an entrance or lobby that needed a key to get out.

NYC Building Code 2022, Chapter 10 as amended by Local Law 77 of 2023, section 1010.1.9.8 (1010.1.9.9 covers push bars with a built-in switch). Read it on nyc.gov. Complaints: HPD Housing Maintenance Code Complaints, NYC Open Data ygpa-z7cr, entrance and lobby doors, 2025.

Have it done to code

The four parts we install

  1. Magnetic lock mounted on a steel door frame with a dome camera above it 1

    The magnet

    An electromagnet on the frame and a steel plate on the leaf, sized to the opening, with nothing on the outside to pick or pry.

  2. Keypad access reader mounted beside a door in Manhattan 2

    The reader outside

    Keypad, fob, fingerprint or phone, managed from the cloud like the rest of our access control installation. You add or remove a person without touching the hardware.

  3. Entrance with a video intercom and access reader at a Long Island distributor 3

    The way out

    An exit button, a motion sensor or both on the inside, so nobody needs a key or code to leave.

  4. Access control and power panels beside a network rack in a Queens apartment building 4

    Power and the fire alarm

    A power supply and controller in the closet, wired so the magnet lets go when the fire alarm trips or the power drops.

How the price is set

Each entrance is priced on its own after a free visit, and you get the number in writing before we start.

  • 1How many entrances and gates
  • 2Frame material and swing
  • 3The reader you pick
  • 4Distance back to the closet
  • 5Fire alarm tie-in

Before you book

QuestionAnswer
How strong is a mag lock?Common models hold about 600 or 1,200 pounds. We pick the holding force by the opening, so a heavy lobby entrance gets more than an inside suite.
Can it go on the entrance we already have?Usually, yes. The magnet mounts to the existing frame and the plate to the leaf, so nothing gets replaced. We check the frame on the visit.
Will it work with our intercom?Yes. The intercom's release opens it, so buzzing someone in works the same as it does today.
Does a mag lock wear out?The magnet has no moving parts, so there is little to wear. On a service call we check the keypad or reader, the release button and the power supply.
Free estimate

Get a free estimate for your entrances

Tell us how many openings. We visit, check the frames and the fire alarm and send the price in writing.

929-299-8400
Step 1 of 2 · What do you need?
Step 2 of 2 · Where should we call?

For: Access control

Call nowFree estimate